Coaxial Jumper Cable SF 3/8''-50-FRNC, 7-16 Male Right Angle to N Male Right Angle, 1 Meter
coaxial jumper cable sf 3/8''-50-frnc, 7-16 male right angle to n male right angle, 1 meters
coaxial jumper cable sf 3/8''-50-frnc, 7-16 male right angle to n male right angle, 1 meters
coaxial jumper cable sf 3/8''-50-frnc, 7-16 male right angle to n male right angle, 1 meters

Coaxial Jumper Cable SF 3/8''-50-FRNC, 7-16 Male Right Angle to N Male Right Angle, 1 Meter

  • Customized packaging length and outer jacket printing to meet customer OEM requirements.

  • Widely used for passive DAS applications.

  • More stable and reliable connector installations by injecting process.


Technical Datasheet

Compliances

Specification of Coaxial Jumper Cable SF 3/8''-50-FRNC, 7-16 Male Right Angle to N Male Right Angle, 1 Meter

General Specifications

FlexibilitySuper-flexible
Jacket ColorBlack
Performance NoteAttenuation guaranteed within the tolerance ±10%
Structure NoteDimension guaranteed within the tolerance ±1%
Nominal Cable Size3/8 in
Connector 17/16 DIN male right angle
Connector 2N male right angle
Frequency BandDC - 4 GHz
Insertion LossCable loss + Connector loss (0.1*√FGHz)
Return Loss≤-28dB @DC-1GHz

≤-26dB @1.0-2.2GHz

≤-23dB @2.2-3.0GHz

≤-22dB @3.0-3.8GHz
PIM (900MHz, 3rd Order)≤-160dBc@2×43dBm
Impedance50 ohms±1 ohm


Cable Specifications

Maximum Available Frequence15 GHz
Cut-off Frequency17 GHz
Velocity Ratio82%
Peak Power7.2 kW
Insulation Resistance5000 MΩ·km
DC Breakdown Voltage2300 V
Nominal Capacitance82 pF/m
Nominal Inductance0.195 μH/m


Cable Material

Inner ConductorCopper-Clad Aluminum Wire
DielectricPhysical Foam Polyethylene
Outer ConductorHelical Corrugated Copper Tube
JacketFRNC


Attenuation

Frequency (MHz)Attenuation (dB/100 m)Attenuation (dB/100 ft)Average Power (kW)
0.50.270.0813.20
10.380.1213.20
1.50.460.1413.20
20.540.166.92
101.210.374.87
201.710.523.97
302.110.643.06
502.730.832.14
883.651.111.98
1004.211.281.87
1084.461.361.76
1504.811.471.61
1745.201.581.49
2005.591.701.21
3006.922.111.04
4008.062.460.98
4509.402.870.86
50010.003.050.85
51210.403.170.83
60010.893.320.77
70011.883.620.72
80012.873.920.65
82413.864.220.59
90014.164.320.51
96014.364.380.48
100014.954.560.47
125016.535.040.45
150017.725.400.42
170021.586.580.38
180022.186.760.35
200023.277.090.35
210025.357.730.32
220027.238.300.31
240028.918.810.28
300036.8311.230.22
400043.8613.370.19
600050.3015.330.16
800044.9013.690.16


Return Loss/VSWR

Frequency BandVSWRReturn Loss (dB)Tolerance
DC-1.0GHz1.0828.35%
1.0-2.2GHz1.1224.95%
2.2-3.0GHz1.1523.15%
3.0-3.8GHz1.1722.15%


Mechanical Specifications

Bend ProtectionMolding
LabelWrap Sticker
Bending Radius (Single)≥15 mm
Bending Radius (Repeated)≥30 mm
Number of Bending (Typical)≤15
Tensile Strength950N
Connector Tightening Torque≤30N.m for 7/16 DIN Type

≤8N.m for 4.3-10 Type

≤8N.m for mini-DIN Type

≤1.5N.m for N Type

≤1.8N.m for NEX10 Type
Unit Packing1pcs in PE bag
Package PackingQuality Carton


Environmental Specifications

Installation Temperature-20 °C to +55 °C
Operating Temperature-20 °C to +85 °C
Storage Temperature-25 °C to +85 °C
Relative Humidity5% - 95%
IP RatingMated IP68, 1m, 1.5hrs, 20 deg-C


Regulatory Compliance

ISO 9001:2015Compliant
ROHSCompliant
China RoHSCompliant
UK RoHSCompliant
REACHCompliant